Dryer sizing inputs
g/cm³
Enter a density greater than 0.
Use the apparent/bulk density of the pellets. Numerically, 1 g/cm³ = 1 kg/L.
h
Enter a drying time greater than 0 hours.
g/shot
Enter a shot weight greater than 0 grams.
Total dried material consumed by one complete injection cycle.
s
Enter a cycle time greater than 0 seconds.
Required dryer capacity
Required dryer volume
208.88
L
Volume required to provide 4 hours of material residence time.
Shots per hour
180
Material throughput
49.61 kg/h
Volume throughput
52.22 L/h
Material inventory
198.43 kg
Required volume is based on continuous material consumption during the selected drying time.
Check an existing dryer
L
Enter a dryer volume greater than 0 liters.
Enter the usable material volume of the dryer you want to evaluate.
Material capacity
47.50 kg
Residence time
0.96 h
Whole shots available
172
Volume difference
−158.88 L
Required-capacity coverage
23.9%
Dryer is too small for the required drying residence time.
Formula & detailed calculation
Follow material throughput from molding cycle to required dryer volume.
1. Cycle rate
\[N_{shots/h}=\frac{3600}{t_{cycle}}\]
2. Material throughput
\[\dot{m}=\frac{N_{shots/h}\times m_{shot}}{1000}\]
3. Volume throughput
\[\dot{V}=\frac{\dot{m}}{\rho}\]
With apparent density in g/cm³, the numerical value is also kg/L, so kg/h ÷ kg/L gives L/h directly.
4. Required dryer volume
\[V_{dryer}=\dot{V}\times t_{dry}\]
Current sizing calculation
Existing dryer check
Important: this helper sizes volume from material throughput and required residence time. Actual dryer selection can also depend on manufacturer recommendations, usable hopper fill level, airflow, material behavior, and operating margin.