Process Development

Dryer Volume

Calculate the dryer volume required from material throughput and drying residence time.

Dryer sizing inputs

g/cm³
Enter a density greater than 0.
Use the apparent/bulk density of the pellets. Numerically, 1 g/cm³ = 1 kg/L.
h
Enter a drying time greater than 0 hours.
g/shot
Enter a shot weight greater than 0 grams.
Total dried material consumed by one complete injection cycle.
s
Enter a cycle time greater than 0 seconds.

Required dryer capacity

Required dryer volume
208.88
L
Volume required to provide 4 hours of material residence time.
Shots per hour
180
Material throughput
49.61 kg/h
Volume throughput
52.22 L/h
Material inventory
198.43 kg
Required volume is based on continuous material consumption during the selected drying time.

Check an existing dryer

L
Enter a dryer volume greater than 0 liters.
Enter the usable material volume of the dryer you want to evaluate.
Material capacity
47.50 kg
Residence time
0.96 h
Whole shots available
172
Volume difference
−158.88 L
Required-capacity coverage 23.9%
Dryer is too small for the required drying residence time.

Formula & detailed calculation

Follow material throughput from molding cycle to required dryer volume.

1. Cycle rate

\[N_{shots/h}=\frac{3600}{t_{cycle}}\]

2. Material throughput

\[\dot{m}=\frac{N_{shots/h}\times m_{shot}}{1000}\]

3. Volume throughput

\[\dot{V}=\frac{\dot{m}}{\rho}\]

With apparent density in g/cm³, the numerical value is also kg/L, so kg/h ÷ kg/L gives L/h directly.

4. Required dryer volume

\[V_{dryer}=\dot{V}\times t_{dry}\]

Current sizing calculation

Existing dryer check

Important: this helper sizes volume from material throughput and required residence time. Actual dryer selection can also depend on manufacturer recommendations, usable hopper fill level, airflow, material behavior, and operating margin.